Argon CO2 Gauges Pressure Reducer Mig Flow Meter Outlet Male Thread G5/8-14 (CGA540)
Features:
One gauge shows pressure for carbonating and dispensing.The other gauge displays how much CO2 is left. Easy to use dial for pressure adjustment from min to max. Pressure safety relief valve which can be pulled to release pressure when disconnecting. Forged brass body, accurate machining, chrome plated finish, more durable. Economy style flow meter regulator. Single stage piston design. Machined brass body. Combination of regulator and flow meter as one unit. Polycarbonate flow tube and outer cover are impact resistant for maximum durability. Compact lightweight construction. Designed for MIG & TIG applications and provide accurate regulator of gas flow. Dual scale gauge with unbreakable polycarbonate lens for durability.Specifications:
| Adjustment configuration | Header configuration | Table parameters | |||||
| Applicable Gas | Input pressure | Output pressure | Reference flow | Connection intake thread | Outlet thread | ||
| Green (handwheel) | High pressure 25mpa | Mpa | Mpa | m3/h | Iniet Thresad | Outiet Thresad | |
| Low pressure 2.5 | Oxygen | 15 | 0.1~0.85 | 50 | G5/8-14RH(F) | M16*1.5RH(F) | |
| Applicable Gas | Input pressure | Output pressure | Reference flow | Connection intake thread | Outlet thread | ||
| Red (handwheel) | High pressure 4mpa | Mpa | Mpa | m3/h | Iniet Thresad | Outiet Thresad | |
| Low pressure 0.25 | Acetylene | 3 | 0.01~0.15 | 15 | Bottle holder | M16*1.5LH(M) | |
| Applicable Gas | Input pressure | Output pressure | Reference flow | Connection intake thread | Outlet thread | ||
| Red (handwheel) | High pressure 3mpa | Mpa | Mpa | m3/h | Iniet Thresad | Outiet Thresad | |
| Black (handwheel) | Low pressure0.3 | Propane,natural gas LPG | 2 | 0.01~0.18 | 15 | M22*1.5 LH(M) | M16*1.5LH(M) |
| Applicable Gas | Input pressure | Output pressure | Reference flow | Connection intake thread | Outlet thread | ||
| Black (handwheel) | universal head | Mpa | Mpa | m3/h | Iniet Thresad | Outiet Thresad | |
| T type (iron) | High pressure 25mpa | Argon, Nitrogen, Helium | 15 | 0.03~0.85 | 40 | G5/8-RH(F) | M16*1.5RH(F) |
| Low pressure 2.5 | Ar ,N2,He | ||||||
| General Medium (Applicable Gas) | Input pressure | Output pressure | Reference flow | Connection intake thread | Outlet thread | ||
| Mpa | Mpa | m3/h | Iniet Thresad | Outiet Thresad | |||
| T type (copper) | universal head | O2 | 15 | 0.05~1.2 | 60 | G5/8-RH(F) | M16*1.5RH(F) |
| Black (handwheel) | High pressure 25mpa | Ar | 15 | 0.03~0.85 | 50 | G5/8-RH(F) | M16*1.5RH(F) |
| Low pressure 2.5 | H2 | 15 | 0.05~0.56 | 50 | W21.8-14LH(M) | M16*1.5LH(M) | |
| N2 | 15 | 0.07~1.2 | 60 | G5/8-RH(F) | M16*1.5RH(F) | ||
When the pressure reducer is correctly installed on the cylinder valve, the power is turned on, and after opening the cylinder valve, the imported high pressure gas enters the low pressure chamber through the throttle gap of the valve and the valve seat through the high pressure chamber, and is sent to the low pressure chamber through the flow regulating valve. user. The power supply is heated by the heater and the heater is automatically adjusted to a certain temperature.
When the adjustment pressure exceeds the allowable value of one chamber, the safety valve will automatically open the deflation, and when the pressure is reduced to the allowable value, it will automatically close.
| Model | Input pressure | Output pressure | Flow | Intake connection thread | Outlet connection thread |
| WX-02 | 15 Mpa | 0-0.6Mpa | 0-50L | G5/8 | M12*1 |
Product Usage:
This product is a pressure reducing device that adjusts the high pressure gas in the cylinder to the required practical pressure. Mainly used in welding, cutting and chemical, medical and health, electronics industry and other fields.
Instruction manual Correct use - safety guarantee
1. When installing the gas pressure reducer, check the consistency of the gas cylinder valve connection thread specifications, and pay attention to remove impurities and grease from the joints to prevent debris from entering the pressure reducer.
2. When opening the cylinder valve, the person should stand on the side of the pressure reducer and should not face it in front to avoid accidents. The cylinder valve should be opened slowly. At this time, the pressure gauge high pressure gauge will indicate the internal pressure of the cylinder. Then adjust the pressure reducer output knob (adjustment lever) (clockwise). The low pressure gauge will indicate the working pressure of the output.
3. The safety valve has been strictly adjusted at the factory. When the regulating pressure exceeds the used value, the safety valve will be automatically vented. For this reason, the user is not allowed to adjust or disassemble it.
4. At the end of the work, the cylinder valve must be closed and the remaining gas from the pressure reducer.
5. If the regulator is damaged or has any abnormality, please stop using it immediately, and you must entrust the manufacturer to carry out maintenance.
6. Correctly use the gas specified by the pressure reducer. This product should be used during the process to avoid impact and should not be used in the environment where the medium is corroded.
7. Can not use dry siphonic cylinders.
8. The use of pressure reducers should be strictly implemented by the State Labor General Administration (gas cylinder safety supervision regulations) and (dissolved acetylene gas cylinder safety supervision regulations).
Package List:
1*Host
1*An outlet thread
Note:
The manufacturer will not be responsible for any malfunctions and adverse consequences caused by the operation and precautions in the instructions and the disassembly and repair.










About feedback:
If you are satisfied with our products, Pls give us 5 Stars
Характеристики
- Номер модели
- pressure reducer
- Бренд
- Hilitand
- Output pressure
- 0.25Mpa
- Flow adjustment range
- 1-10L/min
- Safety valve
- 0.5Mpa automatic exhaust
- Export thread
- M12x1